Product Specs
Generator Set Specifications
- Gas Standby Rating
- 1000 ekW @ 0.8pf
- Fuel Type
- Natural Gas, Hydrogen Blend (up to 5%)
- Emissions/Fuel Strategy
- U.S. EPA Certified for Non-Emergency Stationary Genset
- RPM
- 1800 rpm
- Frequency
- 60 Hz
- Compression Ratio
- 9.7
- Displacement
- 3173 in³
Engine Specifications
- Engine Model
- G3512
- Displacement
- 3173 in³
- Aspiration
- TA
- Bore
- 6.7 in
- Stroke
- 7.5 in
Generator Set Dimensions
- Length
- 205.7 in
- Width
- 90 in
- Height
- 99.4 in
- Weight
- 27500 lb
Standard Equipment
-
- Air Cleaner
-
- Dual element single stage with enclosure and service indicator
-
- Starting
-
- Dual electric starters
-
- Cooling
-
- Standard Ambient Radiator
- JW & SCAC engine driven pumps
-
- Mounting System
-
- Rails
-
- Controller
-
- Cat ECS 100
-
- Telematics
-
- Ethernet
-
- Alternator
-
- Random wound
- Permanent Magnet (PM) Excitation
-
- Alternator Attachments
-
- Integrated Voltage Regulator (IVR)
- Stator and bearing temperature monitoring and protection
-
- Power Termination
-
- Busbar NEMA
-
- Certifications
-
- ICES for Canada
Attachments
-
- Starting
-
- Charging Alternator - 45A
- Battery charger - 20A
- Battery charger - 35A
- Jacket water heater
-
- Cooling
-
- No Radiator
- JW outlet connection (RH or LH)
-
- Fuel System
-
- Gas Train (NFPA/CSA)
- Gas Pressure Sensor
- Double Shutoff Solenoid
- Gas Knockdown Regulator
-
- Lubrication System
-
- Oil level regulator
- Electric pre-lube pump
-
- Crankcase Ventilation System
-
- Positive crankcase ventilation
- Explosion relief valve
-
- Muffler
-
- Industrial grade (15 dB)
- Residential grade (18 dB)
- Spark arresting
- Exhaust SCR System
-
- Mounting System
-
- Rubber
- Spring vibration Isolators
- Seismic rated vibration isolators
-
- Controller
-
- Cat ECS 200
-
- Controller Attachments
-
- Remote annunciator module
- Remote HMI Panel
- Discrete I/O module
- CAN2 wiring
- Remote monitoring software
-
- Telematics
-
- Cellular
-
- Alternator
-
- Form wound
-
- Alternator Temperature Rise (over 40°c Ambient)
-
- 80°C
- 105°C
- 125°C
- 150°C
-
- Alternator Output Voltage
-
- 440V
- 480V
- 600V
- 2400V
- 4160V
-
- Alternator Attachments
-
- Anti-condensation space heater
- Current Transformer (CT)
-
- Power Termination
-
- Circuit breaker
-
- Circuit Breaker
-
- 1200A
- 1600A
- 2000A
- UL
- 3-pole
- Manually operated
- Electrically operated
-
- Trip Unit
-
- LSI
- LSI-G
- LSI-P
- LSIG-P
- UV
-
- Ancilliary Equipment
-
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls
-
- Enclosure
-
- Weatherproof
- Sound attenuated (80 dBA)
-
- Certifications
-
- UL 2200 Listed
-
- Extended Service Terms
-
- 2 year
- 3 year
- 5 year
- 10 year
-
- Extended Service Coverage
-
- Silver
- Gold
- Platinum
- Platinum plus