MacAllister Power Systems

LocationsCareersContact UsMacAllister.com
  • Home
  • Equipment
    • Electric Power
      • Generators
        • Cat® GC Diesel Generator Sets
      • UPS
    • Industrial Engines
    • Rental Power
      • Power Systems Rentals
      • Temperature Control Equipment Rentals
      • Air Compressor Rentals
      • Event Services
    • Used Generators
      • Decommissioning Services & Asset Recovery
    • Blue Bird Bus
  • Parts & Service
    • Online PartStore
    • Parts Information
    • Service Information
      • Generator Service
      • Industrial Engine Service
  • Solutions
    • Finance
    • Paperless Invoicing
    • Extended Service Coverage (ESC)
    • Decommissioning Services & Asset Recovery
    • Sell Your Generator
    • Combined Heat and Power
    • Online Tools
    • Contract Purchasing
    • Engineering Toolbox
  • About
    • Contact Us
    • Locations
      • Fort Wayne
      • Indianapolis
      • Indianapolis – Brookville Rd
      • Lafayette
      • South Bend
      • Terre Haute
      • Washington
    • Careers
    • Legal Notices
Home / Solutions / Engineering Toolbox / Generator Set Ventilation

Generator Set Ventilation

It’s been estimated that up to 10 percent of the fuel consumed by the average internal combustion engine is dissipated to the surrounding area as heat. This heat must be removed to maintain proper and safe gen set operation. This is usually accomplished by induced draft or ventilation fans as shown in figures 4 and 5.

The most efficient method of removing this heat is with a system that pulls air past switchgear, then over the engine, from back to front. If air curtains are used, the airflow should gather this radiant heat just above the gen set, which offers greater efficiency and less exposure to high air velocities in other areas of the gen set room. Airflow should be upward around each engine or in the case of engines with mounted radiators, across the back of the engine to the front. The ventilation system should sufficiently move air to control temperature in all areas of the engine room.

Ventilation Fan Sizing

The following equations provide the proper airflow (cfm or m3/s velocity for a given gen set installation, assuming 100 F (38C) ambient temperature:

Airflow (cfm or m3/s should increase 10 percent for every 2,500 feet (760m) above sea level.

 

Where:

V = ventilating air

H = heat radiation

delta T = Permissible temperature rise in engine room (degrees F or C)

Density of air at 1008F = 0.07 lb/cu ft (1.099 kg/m=)

Specific heat of air = 0.24 Btu/8F (0.017 kW/8C).

Sound Control

Minimizing engine noise while maintaining adequate cooling presents come design challenges. Insulated air ducts and close attention to air inlet and outlet locations can greatly minimize noise problems. Unfortunately, air louvers are not adequate to contain engine noise.

Engineers at Caterpillar as well as engineers at our dealership have worked on several installations where ventilation noise was a key design consideration. We can share the experience gained with you during your design phase.

Cold Weather Considerations

In colder climates, the desired temperature rise needed to maintain optimum engine operating temperature could be as much ad 80 F (27C) instead of the usual 10 to 20 F (5.5 to 11C). In these cases, it is better to specify a number of smaller fans tan one large fan to supply ventilation air. This also allows you to adjust ventilation if the gen set operates at a lower output. Movable louvers positioned to redirect engine heat back into the room until the jacket water temperatures reach 190 F (88 C) may be used. Then, these louvers close so ventilation air is exhausted.

Achieving correct ventilation levels is best accomplished during the design phase— we can help you at this juncture to best plan for ventilation needs.

Contact Us
  • Extended Service Coverage (ESC)
  • Finance
    • Credit Application
  • Paperless Invoicing
  • Online Tools
  • Decommissioning Services & Asset Recovery
    • Decommissioning & Equipment Purchasing FAQ
    • Sell Your Generator
    • Free Appraisal
    • Contact Us for Decommissioning Services
  • Combined Heat and Power (CHP)
  • Contract Purchasing
  • Engineering Toolbox
    • Generator Set Ratings
    • Generator Set Specifications
    • Generator Set Foundations
    • Generator Set Rooms & Enclosures
    • Generator Set Ventilation
    • Generator Set Noise
    • Generator Set Starting Systems
    • Generator Set Cooling Systems
    • Generator Set Exhaust Systems
    • Generator Set Engine Governors
    • Generator Set Fuels
    • Generator Set Sizing
    • Generator Set Motor Starting
    • Other Generator Technical Considerations
    • Generator Set Testing
    • Automatic Transfer Switches

MacAllister Power Systems

6300 Southeastern Ave
Indianapolis, IN 46203

(800) 382-1896

24-Hour Rental Hotline
866-622-7367

Contact Us

New / Rental / Used Equipment

Generator Sets
Uninterruptible Power Supplies
Industrial Engines

Generator Rentals
Electrical Equipment Rentals
Air Conditioner Rentals
Chiller & Cooling Tower Rentals
Heater & Dehumidifier Rentals
Air Compressor Rentals

Used Generators

8 Convenient Locations

Fort Wayne
Indianapolis - Brookville Rd
Indianapolis - HQ
Indianapolis - Rental & Used
Lafayette
South Bend
Terre Haute
Washington

More MacAllister Sites

MacAllister Machinery
MacAllister Ag
MacAllister Hydrovac
MacAllister Kubota
MacAllister Outdoors
MacAllister Railroad Machinery
MacAllister Rentals
MacAllister Transportation
MacAllister Used
Michigan CAT

Copyright © 2022 MacAllister Machinery Co., Inc.    All rights reserved.    Legal Notices  /  Copyright  /  Privacy Policy